LGT-100 is a kind of explosion-isolation in-situ probe type tunable laser gas analyzer, which is developed for industrial online analysis and environmental online monitoring. It can online analyze HCl under various complex working conditions. The measured gas concentration ranges from constant to trace
Features
In-situ measurement is adopted without pretreatment system to avoid sampling adsorption, blockage and component damage in preprocessing.
Integrated structure: no moving parts, with good reliability and stability.
Adopt "Single Line Spectrum" Technology, free from cross interference of background gas.
The optical path realizes uncoupling direction adjustment, simple optical path adjustment at site.
Application
Analysis of gas recovery of converter gas; analysis of CDQ circulating gas; oxygen analysis of coke oven gas after electric detarring; blast furnace coal injection gas analysis; analysis of ammonia escaping gas in cement industry; trace CO detection & analysis in electric power, cement, environmental protection and other industries; trace HCl analysis in environmental protection and chemical industry, etc.
Specifications
Accuracy: ≤1%F.S
Linearity error: ≤1%F.S
Zero drift: ≤1%F.S./half a year
Span drift: ≤1%F.S./half a year
Ex-mark: ExdIICT6 GB
IP grade: IP66
Response time: ≤1s (T90).
Analog input: 2x4-20mA input
Analog output: 2x4-20mA output
Digital communication: RS485/RS232/GPRS
Working temperature: -20℃~60℃
Measuring range: 0 - 200 mg/Nm3 (customizable)
Resolution: ≤1 ppm/ mg/Nm3
Power supply: 24 VDC, 20 W
EU Type Examination Certificate CML 18ATEX1395X Issue 1