The CEMS-5000C is a CO2 monitoring system developed by our company based on years of experience in flue gas monitoring. The system consists of three parts: a CO2 monitoring subsystem, a flue gas parameter monitoring subsystem (temperature, pressure, velocity), and a system control & data acquisition & processing subsystem.
Advanced TDLAS technology, long optical range, high resolution and fast response time;
Multi-stage dust filtration technology and timed blowback for the sampling probe to avoid easy probe
blockage and make it adaptable to high dust, high humidity, high temperature, high corrosive and other harsh environments;
High degree of automation, real-time collection of detailed status information of the system, which is the soundest basis for data validity audits;
Intelligent design, with automatic zeroing, range overrun alarm, sampling probe temperature alarm, condenser temperature alarm, heating temperature alarm, fault alarm and other functions;
Other parameters and factors can be expanded according to actual needs
Domestic waste incineration, hazardous waste incineration, medical waste incineration, thermal power generation, iron and steel smelting, petroleum smelting and petrochemistry, coal, oil, natural gas extraction and other occasions.
Parameters | CO2 , humidity, temperature, pressure, velocity |
Linearity error | ±2%F.S. |
Repeatability | ≤2% |
Zero drift | ±2%F.S./d |
Span drift | ±2%F.S./d |
Response time | ≤200s |
Heat tracing temperature | 120℃~140℃ |
Power supply | AC (220±22)V; (50±1)Hz |
Rated power | ≈ 5000W (2500W for the heat tracing pipe) |
Ambient temperature | 15℃~35℃ (indoor); -20℃~50℃ (outdoor) |
Ambient humidity | ≤ 85%RH, non-condensing |
Flow rate | 2L/min |
Dimension | 800mm*600mm*1900mm |
Weight | 300kg |
Output | DC 4-20mA,RS232/RS485 |