EmailThe PGA-5000 Process Gas Analyzer is designed for measurements of multiple components and multiple ranges in hazardous areas. The product can be configured with modules ac-cording to onsite requirements.It can measure O2, CO,CO2,CH4, SO2, NO,H2, etc. from major to minor if configured with a laser module, thermal conductivity module, electrochemical oxygen module. Tunable diode laser absorption spectroscopy (TDLAS) makes the PGA-5000 capable of measuring O2,CO,CO, etc.; Thermal conduction technology makes it able to measure H2, Ar, CO2, etc.. Electrochemical technology enables it for O2 measurements.
Measurement method
TDLAS,thermal conduction,electrochemical(selectable)
Response time
Within 20 s(related to configured modules)
Indication error
Within ±1% F.S.(related to configured modules)
Repeatability
Within 1%
Zero drift
Within ±1% F.S./6 months(TDLAS)
Span drift
Within ±1% F.S./6 months(TDLAS)
Flameproof marking
Ex db IIC T6 Gb
IP rating
IP66
Analog output
4x4-20mA outputs (isolated, max load 750Ω)
Analog input
4x4-20mA inputs(temp,pressure compensation)
Switch output
(6xpassive +2xactive)outputs(DC 24+2.4V. 1A)
Switch input
4xinputs (optional)
Comm interface
RS485/RS232
Power supply
DC 24V
Ambient temperature
(-30~60)℃
Ambient humidity
Within 95% RH